Pinnacle-systems SLT Series Manual de usuario Pagina 26

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 25
A-2
Appendix A:
Regulations & Guidelines for Safe Operation
SLT Series
Light CurLight Cur
Light CurLight Cur
Light Cur
tain tain
tain tain
tain
TT
TT
T
est Prest Pr
est Prest Pr
est Pr
ocedurocedur
ocedurocedur
ocedur
ee
ee
e
Use a dowel rod (or similar object) with a diameter equal
to the M.O.S. (Minimum Object Sensitivity) of the guard
you are testing. Move the rod through the field of the
curtain (i.e. top to bottom for vertically mounted cur-
tains). Repeat this test close to the Emitter pylon, close
to the Receiver pylon, in the middle between the py-
lons, and most importantly in front of the operator posi-
tion.
Make sure the curtain indicates a “Blocked” condition
(RED light) when the rod is in the field of the curtain.
Check and make sure the machine cannot move when
the curtain shows “Blocked”. If the machine can oper-
ate while the curtain shows a “Blocked” condition, then
re-examine your wiring.
NOTE: Always use both safety relays in your ST OP
circuit(s).
If the curtain does not show “Blocked” when the rod is
in the field: Check to make sure the rod is truly in the
curtain’s field, and re-check the curtain’s Minimum Ob-
ject Sensitity (including AutoBlank and Floating blank
options that change the M.O.S.).
Infrared light from the curtain may be reflecting around
the rod due to reflective material too close to the curtain’s
field. In this case, you will have to move the curt ain
pylons back away from the reflective material and re-
peat the test over again. The curtain’s power level can
also be reduced by the factory.