3
Speci cations
NSD Safety Mat System
2
NSD-TR-01
Controller
(Metal Box)
NSD-DR-01
Controller
(Basic DIN-rail)
NSD-DR-04
Controller
(DIN-rail with Diagnostics)
Enclosure:
NEMA 12, 13, IP 54 NEMA 1, IP 32 NEMA 1, IP 32
Input Power:
120VAC +/- 10% @ 3 watts
50-60 Hz fused
24VDC +/- 20% @ 7 watts 24VDC +/- 20% @ 7 watts
Category/Type:
4 4 4
Relay Style:
Monitored force-guided captive
contact safety relays
Monitored force-guided captive
contact safety relays
Monitored force-guided captive
contact safety relays
Relay Configuration:
2 N.O. Safety Relays (closed
when circuit activated)
1 Aux Output N.O. or N.C
2 N.O. Safety Relays (closed
when circuit activated)
1 Aux Output N.O. or N.C
2 N.O. Safety Relays (closed
when circuit activated)
1 Aux Output N.O. or N.C.
1 Fault Relay N.O.
Safety Relay Rating:
4A @ 220VAC 4A @ 220VAC 4A @ 220VAC
Reset Provisions:
Manual or Automatic Manual or Automatic Manual or Automatic
Controller Response
Time:
15 msec. 15 msec. 19 msec per mat input used
Self-Checking
Intervals:
Every 20 msec. Every 20 msec. Every 20 msec.
Number of Isolated
Zones:
1 to 13 (customer specified) 1 per controller 1 per controller
Maximum Number of
Mats:
20 20 4 with homerun wiring
20 with daisy chain wiring
External Reset
Provision:
Green push button Green push button Green push button
Indicators:
Internal (on board):
Yellow LED
= +5VDC power
supply
Red LED = Normally dim,
brighter when mat is stepped
on. Cut wire detected when
not lit.
Green LED = Relay contact
detected closed when it should
have been open when not lit.
Must reset power to clear.
Green LED(s) = next to
each relay (3)
Red LED
= +12V
Yellow LED = +5V
Green LED
= -5V
Red LED = +12VDC
Green LED
= +20VDC
Yellow LED
= +5VDC
Green LEDs
= one for each
relay (4 total)
External:
Red LED
= 1 or both relays are
de-energized.
Green LED
= All relays are
energized.
Red LED
= 1 or both relays are
de-energized.
Green LED
= All relays are
energized.
Yellow LEDs = 2 to show on/off
mat.
Yellow LED
= relay fault if it
turns off.
Red LED = 1 or both relays are
de-energized.
Green LED
= All relays are
energized.
Yellow LEDs = 1 for each mat
status — (4 total)
Diagnostic Message
Display:
N/A N/A Built-in
DeviceNet:
N/A N/A Add suffix DN to Model #. See
next page for additional
information.
Warranty:
2 years 2 years 2 years