10
ACCESSIBLE CONNECTIONS (Din-Rail controller)
Internal:
J1 Diagnostics display plug (used by remote status display option)
The Plug is located under the top cover on the left side of the controller
External:
POWER/OUTPUT PLUG
+POS, -NEG, EARTH GROUND (24VDC ONLY)
Safety relay N.O. output (dry contact)
Safety relay N.O. output (dry contact)
Auxiliary relay N.C., COM, N.O.
Fault relay N.O. (open when faulted)
INPUT / OUTPUT PLUG
+pos, -neg External relay checking (option)
24vdc applied across these terminals when external relay is de-energized
Remote external zone reset (Ground to reset zone)
Auxiliary inputs (Ground to activate feature)
+24vdc input (Common for terminals 3,4,5) (jumper from term #1 Power/Output)
Optional remote RED “STOP” indicator output (Grounded when RED)
Optional remote GREEN “RUN” indicator output (Grounded when GREEN)
MAT 1,2,3,4 INPUT
20VDC output to mat (1=blue, 2=white)
voltage between 1 & 2 alternates
Return from mat (3=black, 4=brown)
NOTE: Canadian market wiring is black, red, red, black with 18-guage wiring size.
DEVICENET PLUG (DB-9 female)
CANL, CANH (twisted pair data lines)